LAB REPORT EXPLAINED

This BPC-157 report provides a useful combination of measured peptide content, purity and traceable sample details. Here is a straightforward guide to the findings, with the original certificate and a way to check its record with the laboratory.
What the BPC-157 10 mg certificate reports
| Field | Reported result |
|---|---|
| Sample / report | BPC-063 / COA-2026-SC-00978 |
| Label claim | 10.00 mg |
| Net peptide content | 10.88 mg |
| Label accuracy | 108.8% |
| Chromatographic purity | 99.6% |
| Analyzed / PDF date | August 14, 2026 |
The reported peptide content is 0.88 mg above the nominal 10 mg claim. The 108.8% label-accuracy figure expresses that measured amount relative to the claim; it is not a purity score, and it is not a recommendation to adjust a dose. The certificate marks the result as passing against its stated criteria.
Purity and content answer different questions
Chromatographic purity describes the target peptide’s share of the integrated analytical signal under the reported method. Net peptide content is a quantity in milligrams. Neither field should be confused with the total powder mass. The certificate’s purity definition excludes excipients, counterions and residual water from what the percentage describes.
This distinction is especially visible in the sample information: total mass is 78.8 mg, while net BPC-157 content is 10.88 mg. The report does not identify the remainder as additional BPC-157.
Identity and analytical details
The certificate identifies BPC-157 and reports LC-MS/MS analysis using Method A. It lists a 7.062-minute retention time and the monitored precursor and product-ion transitions. Those details give context for the laboratory’s identification and measurement; the certificate alone is not a full method-validation dossier.
BPC-157 10 mg: laboratory report
10.88 mg net peptide content; 99.6% chromatographic purity.
Submitted sample BPC-063 · Report COA-2026-SC-00978 · PDF date August 14, 2026. These results apply to this submitted sample; match your product’s batch documentation before applying them to another vial.
Every page of the actual certificate is displayed below. Select a page to enlarge it, including its original QR code.

How to verify this report with the lab
- Scan the original QR code on page 1 with a phone camera. On the same phone, open the laboratory verification page instead.
- Enter PTC-244WK2MY and select Verify. Check for the certificate confirmation and portal issue date August 15, 2026.
- Open the lab-hosted PDF. Match sample BPC-063, report COA-2026-SC-00978, PDF date August 14, 2026, formulation and analytical results to the pages shown here. The portal sample label is BPC-063_CoA_20260814_030728.
Date distinction: the PDF is dated August 14, 2026; the verification portal lists August 15, 2026. These are displayed separately because the portal does not explain the difference.
We checked the laboratory record and confirmed that its downloadable PDF exactly matches the supplied file. Compare the lab-hosted PDF ↗. This is document verification, not independent retesting. The report does not establish sterility, endotoxin levels, storage stability, clinical effectiveness or safety for human use, and does not validate dosing guidance.
Reading the evidence in context
A certificate is a record of a particular submitted sample. It does not establish that every vial or every later batch has the same composition. Compare the sample identification and formulation with the accompanying batch documentation, and retain the complete report rather than a cropped purity claim.
The reports describe LC-MS/MS analysis. They do not include a sterility result, an endotoxin result, a storage study or a clinical assessment. A confirmed verification code establishes that a document is in the issuing service’s records; it does not independently validate the analytical methods or retest the material.
For a fuller explanation of the fields, see how to read a peptide COA. Browse the research blog for more report reviews.